Monthly Archive: February 2017

CVE-2016-6210

sshd in OpenSSH before 7.3, when SHA256 or SHA512 are used for user password hashing, uses BLOWFISH hashing on a static password when the username does not exist, which allows remote attackers to enumerate...

CVE-2016-6129

The rsa_verify_hash_ex function in rsa_verify_hash.c in LibTomCrypt, as used in OP-TEE before 2.2.0, does not validate that the message length is equal to the ASN.1 encoded data length, which makes it easier for remote...

CVE-2016-5815

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can...

CVE-2016-5813

An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in...

CVE-2016-5811

An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. User controlled input is not neutralized prior to being placed in web page output (CROSS-SITE SCRIPTING). Date published :...

CVE-2016-5809

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user...

CVE-2016-5805

An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to2.10.10. There are multiple instances of heap-based buffer overflows that may allow malicious...

CVE-2016-5803

An issue was discovered in CA Unified Infrastructure Management Version 8.47 and earlier. The Unified Infrastructure Management software uses external input to construct a pathname that should be within a restricted directory, but it...

CVE-2016-5802

An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to 2.10.10. Multiple instances of out-of-bounds write conditions may allow malicious files to...

CVE-2016-5801

An issue was discovered in OmniMetrix OmniView, Version 1.2. Insufficient password requirements for the OmniView web application may allow an attacker to gain access by brute forcing account passwords. Date published : 2017-02-13 http://www.securityfocus.com/bid/94937...

CVE-2016-5798

An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cause a...

CVE-2016-5796

An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. Sending additional valid packets could allow the attacker to cause a crash or to execute arbitrary...

CVE-2016-5786

An issue was discovered in OmniMetrix OmniView, Version 1.2. The OmniView web application transmits credentials with the HTTP protocol, which could be sniffed by an attacker that may result in the compromise of account...