Monthly Archive: February 2018

CVE-2017-15332

Huawei AR120-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR1200 V200R006C10, V200R006C13, V200R007C00, V200R007C01, V200R007C02, V200R008C20, V200R008C30, AR1200-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR150 V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20, V200R008C30, AR150-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR160 V200R006C10, V200R006C12,...

CVE-2017-15331

Huawei AR120-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR1200 V200R006C10, V200R006C13, V200R007C00, V200R007C01, V200R007C02, V200R008C20, V200R008C30, AR1200-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR150 V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20, V200R008C30, AR150-S V200R006C10, V200R007C00, V200R008C20, V200R008C30, AR160 V200R006C10, V200R006C12,...

CVE-2017-15330

The Flp Driver in some Huawei smartphones of the software Vicky-AL00AC00B124D, Vicky-AL00AC00B157D, Vicky-AL00AC00B167 has a double free vulnerability. An attacker can trick a user to install a malicious application which has a high privilege...

CVE-2017-15329

Huawei UMA V200R001C00 has a SQL injection vulnerability in the operation and maintenance module. An attacker logs in to the system as a common user and sends crafted HTTP requests that contain malicious SQL...

CVE-2017-15089

It was found that the Hotrod client in Infinispan before 9.2.0.CR1 would unsafely read deserialized data on information from the cache. An authenticated attacker could inject a malicious object into the data cache and...

CVE-2017-14536

trixbox 2.8.0.4 has XSS via the PATH_INFO to /maint/index.php or /user/includes/language/langChooser.php. Date published : 2018-02-15 http://www.securityfocus.com/bid/103009 TrixBox Multiple Cross Site Scripting Vulnerabilities [CVE-2017-14536]

CVE-2017-12726

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if...

CVE-2017-12725

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish...

CVE-2017-12724

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not...

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible...

CVE-2017-12722

An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the...

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a...