An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available...
A software logic bug creates a vulnerability in an AIX 6.1, 7.1, and 7.2 daemon which could allow a user with root privileges on one system, to obtain root access on another machine. IBM...
When using Distributed Test only (RMI based), Apache JMeter 2.x and 3.x uses an unsecured RMI connection. This could allow an attacker to get Access to JMeterEngine and send unauthorized code. Date published :...
ARM mbed TLS before 1.3.22, before 2.1.10, and before 2.7.0, when the truncated HMAC extension and CBC are used, allows remote attackers to execute arbitrary code or cause a denial of service (heap corruption)...
ARM mbed TLS before 1.3.22, before 2.1.10, and before 2.7.0 allows remote attackers to execute arbitrary code or cause a denial of service (buffer overflow) via a crafted certificate chain that is mishandled during...
The cbstream.sys driver in Carbon Black 5.1.1.60603 allows local users with admin privileges to cause a denial of service (out-of-bounds read and system crash) via a large counter value in an 0x62430028 IOCTL call....
The Windows installer that the Apache CouchDB team provides was vulnerable to local privilege escalation. All files in the install inherit the file permissions of the parent directory and therefore a non-privileged user can...
The Apache Thrift Go client library exposed the potential during code generation for command injection due to using an external formatting tool. Affected Apache Thrift 0.9.3 and older, Fixed in Apache Thrift 0.10.0. Date...
A remote code execution vulnerability exists in Schneider Electric’s StruxureOn Gateway versions 1.1.3 and prior. Uploading a zip which contains carefully crafted metadata allows for the file to be uploaded to any directory on...
An information disclosure vulnerability exists in Schneider Electric’s IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information. Date published...
A security misconfiguration vulnerability exists in Schneider Electric’s IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack....
A security misconfiguration vulnerability exists in Schneider Electric’s IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured...
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric’s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing...