Monthly Archive: March 2019

CVE-2019-1569

The Expedition Migration tool 1.1.8 and earlier may allow an authenticated attacker to run arbitrary JavaScript or HTML in the User Mapping Settings for account name of admin user. Date published : 2019-03-26 http://www.securityfocus.com/bid/107564...

CVE-2019-10106

CMS Made Simple 2.2.10 has XSS via the ‘moduleinterface.php’ Name field, which is reachable via an "Add Category" action to the "Site Admin Settings – News module" section. Date published : 2019-03-26 http://dev.cmsmadesimple.org/bug/view/12004

CVE-2019-10105

CMS Made Simple 2.2.10 has a Self-XSS vulnerability via the Layout Design Manager "Name" field, which is reachable via a "Create a new Template" action to the Design Manager. Date published : 2019-03-26 http://dev.cmsmadesimple.org/bug/view/12002

CVE-2019-10068

An issue was discovered in Kentico 12.0.x before 12.0.15, 11.0.x before 11.0.48, 10.0.x before 10.0.52, and 9.x versions. Due to a failure to validate security headers, it was possible for a specially crafted request...

CVE-2019-10063

Flatpak before 1.0.8, 1.1.x and 1.2.x before 1.2.4, and 1.3.x before 1.3.1 allows a sandbox bypass. Flatpak versions since 0.8.1 address CVE-2017-5226 by using a seccomp filter to prevent sandboxed apps from using the...

CVE-2014-9189

Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote...

CVE-2014-9187

Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code...

CVE-2015-3956

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior accept drug libraries, firmware updates, pump commands, and unauthorized...

CVE-2015-3954

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior give unauthenticated users root privileges on Port 23/TELNET by...

CVE-2015-3953

Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends...

CVE-2015-3952

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira...

CVE-2015-1014

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo...