CVE-2019-19101
A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable...
A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable...
A privilege escalation vulnerability in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.4SP,
In FreeBSD 12.1-STABLE before r356606 and 12.1-RELEASE before 12.1-RELEASE-p3, driver specific ioctl command handlers in the ixl network driver failed to check whether the caller has sufficient privileges allowing unprivileged users to trigger updates...
In FreeBSD 12.1-STABLE before r356089, 12.1-RELEASE before 12.1-RELEASE-p3, 11.3-STABLE before r356090, and 11.3-RELEASE before 11.3-RELEASE-p7, driver specific ioctl command handlers in the oce network driver failed to check whether the caller has sufficient privileges...
In FreeBSD 12.1-STABLE before r356035, 12.1-RELEASE before 12.1-RELEASE-p4, 11.3-STABLE before r356036, and 11.3-RELEASE before 11.3-RELEASE-p8, incomplete packet data validation may result in memory access after it has been freed leading to a kernel panic...
If NiFi Registry 0.1.0 to 0.5.0 uses an authentication mechanism other than PKI, when the user clicks Log Out, NiFi Registry invalidates the authentication token on the client side but not on the server...
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored...
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution...
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. Date published : 2020-04-28...
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. Date published : 2020-04-28...
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the...
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers...
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0...
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1...