Monthly Archive: June 2020

CVE-2020-14069

An issue was discovered in MK-AUTH 19.01. There are SQL injection issues in mkt/ PHP scripts, as demonstrated by arp.php, dhcp.php, hotspot.php, ip.php, pgaviso.php, pgcorte.php, pppoe.php, queues.php, and wifi.php. Date published : 2020-06-29 http://mk-auth.com.br/page/changelog-1...

CVE-2020-14002

PuTTY 0.68 through 0.73 has an Observable Discrepancy leading to an information leak in the algorithm negotiation. This allows man-in-the-middle attackers to target initial connection attempts (where no host key for the server has...

CVE-2020-13896

The web interface of Maipu MP1800X-50 7.5.3.14(R) devices allows remote attackers to obtain sensitive information via the form/formDeviceVerGet URI, such as system id, hardware model, hardware version, bootloader version, software version, software image file,...

CVE-2020-13657

An elevation of privilege vulnerability exists in Avast Free Antivirus and AVG AntiVirus Free before 20.4 due to improperly handling hard links. The vulnerability allows local users to take control of arbitrary files. Date...

CVE-2020-13423

Form Builder 2.1.0 for Magento has multiple XSS issues that can be exploited against Magento 2 admin accounts via the Current_url or email field, or the User-Agent HTTP header. Date published : 2020-06-29 https://anothernetsecblog.com...

CVE-2020-12048

Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the...

CVE-2020-12047

The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. Date published :...

CVE-2020-12045

The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. Date published :...

CVE-2020-12041

The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and...

CVE-2020-12040

Sigma Spectrum Infusion System v’s6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational...