Insufficient control flow management in subsystem in Intel(R) SPS versions before SPS_E3_05.01.04.300.0, SPS_SoC-A_05.00.03.091.0, SPS_E5_04.04.04.023.0, or SPS_E5_04.04.03.263.0 may allow a privileged user to potentially enable escalation of privilege via local access. Date published : 2021-06-09...
Improper initialization in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 and 15.0.22 may allow a privileged user to potentially enable information disclosure via local...
Out of bound read in a subsystem in the Intel(R) CSME versions before 12.0.81, 13.0.47, 13.30.17, 14.1.53 and 14.5.32 may allow a privileged user to potentially enable information disclosure via local access. Date published...
Improper initialization in the BMC firmware for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.48.ce3e3bd2 may allow an authenticated user to potentially enable denial of service via local access. Date...
Buffer overflow in the BMC firmware for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.48.ce3e3bd2 may allow an authenticated user to potentially enable escalation of privilege via adjacent access. Date...
Out of bounds write in the BMC firmware for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.48.ce3e3bd2 may allow an authenticated user to potentially enable escalation of privilege via local...
The host SSH servers of Brocade Fabric OS before Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, and Brocade SANnav before v2.1.1 utilize keys of less than 2048 bits, which may be vulnerable to man-in-the-middle...
Brocade Fabric OS prior to v9.0.1a and 8.2.3a and after v9.0.0 and 8.2.2d may observe high CPU load during security scanning, which could lead to a slower response to CLI commands and other operations....
Brocade SANnav before version 2.1.1 allows an authenticated attacker to list directories, and list files without permission. As a result, users without permission can see folders, and hidden files, and can create directories without...
Running security scans against the SAN switch can cause config and secnotify processes within the firmware before Brocade Fabric OS v9.0.0, v8.2.2d and v8.2.1e to consume all memory leading to denial of service impacts...