CVE-2024-0993
A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
More information : https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formWifiMacFilterGet-8b2c5cb67e2a433cad62d737782a7e0f?pvs=4
Attack vector : NETWORK
Attack complexity : LOW
Privileges required : NONE
User interaction : NONE
Confidentiality impact : HIGH
Integrity impact : HIGH
Base score : 9.8
Base severity : CRITICAL
Exploitability score : 3.9
Impact score : 5.9